Инструментальные кабели для промышленных компьютеров RE-2X(ST)Yv- fl, RE-2X(ST)Yv-fl PIMF RE-2X(ST)2YSWBY-fl, RE-2X(ST)2YSWBY-fl PIMF RE-2X(ST)2YSWAY-fl; RE-2X(ST)2YSWAY-fl PIMF |
RE-2X(St)Y-flInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use but no laying underground. | |
RE-2X(St)Yv-flInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. | |
RE-2X(St)Y-fl PiMfInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology safe sytems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid as well as outdoor use but no laying underground. | |
RE-2X(St)Yv-fl PiMfInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. | |
RE-2X(St)2YSWBY-flInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. | |
RE-2X(St)2YSWBY-fl PiMfInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. | |
RE-2X(St)2YSWAY-flInstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. | |
RE-2X(St)2YSWAY-fl PiMfnstrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. |
- Цена: 260 ₸/м